The recorded hydraulicBus.TFwrdInMea channel spans 303.024 to 323.15 source units in this reference run. It starts at 303.15 and ends at 323.15. The first recorded maximum occurs at 400 seconds and the first minimum at 180 seconds.

The system being tested

The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named Throttle. The source file places it under Systems, Hydraulic Modules. We used the 101 stored values for hydraulicBus.TFwrdInMea over the interval 0 to 1,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hydRes (Pressure Drop). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hydraulicBus.TFwrdOutMea covers 303.024 to 323.142 source units. At 230 s, the primary value is 321.584 and the companion is 304.202. Their signed difference is 17.382 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Ummixed throttle circuit. The simulated hydraulicBus.TFwrdInMea channel runs from 303.024 to 323.15 source units over 1,000 seconds.
Ummixed throttle circuit. The simulated hydraulicBus.TFwrdInMea channel runs from 303.024 to 323.15 source units over 1,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 190 to 200 seconds. Subtracting 304.329 from 311.618 gives 7.289 source units. Its location brackets the change within one saved interval of 10 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hydraulicBus.TFwrdInMea (source units)

hydraulicBus.TFwrdOutMea (source units)

0

303.15

303.15

180

303.0243

303.0243

190

304.3291

303.0247

200

311.6184

303.0586

400

323.15

323.1103

600

323.15

323.1397

800

323.15

323.1416

1000

323.15

323.1416

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.