The archived response ranges from 5 to 85. The median is 35 and the central half of the measurements extends from 18 to 46.5. Those figures use all 107 numeric observations in this source series and retain its original measurement scale.

What was measured

The BERGER data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as measured in-field defect size. It preserves the source scale and its sign. The file contains 3 numeric fields per accepted row.

Spread across the original readings

The tenth percentile is 10 and the ninetieth is 58.8. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 80. This is the range of this sample, rather than a guaranteed operating envelope.

Ultrasonic pipeline defect sizing. The 25th, 50th and 75th percentiles of the measurements are 18, 35 and 46.5.
Ultrasonic pipeline defect sizing. The 25th, 50th and 75th percentiles of the measurements are 18, 35 and 46.5. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 45 after the header. Its response is 35. The overall arithmetic mean is 33.579, so this observation is 1.421 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 28.5, calculated by subtracting 18 from 46.5.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

5

107

10

10

107

25

18

107

50

35

107

75

46.5

107

90

58.8

107

100

85

107

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.