The acoustic pulse travels to the target and back. Use 343 m/s as the assumed sound speed and convert microseconds to seconds before halving the round-trip path. The examples are ideal propagation distances. With echo pulse duration (µs) at 2,000, the worked result is 0.343 on the one-way distance (m) scale.

The recorded quantity and the calculated result

Keep three columns in a commissioning export: the original echo pulse duration (µs), the configuration used in the conversion and the resulting one-way distance (m). Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.

Two points to check independently

Take the neighbouring worked points 1,000 and 2,000 on the input axis. The results are 0.1715 and 0.343, giving a signed difference of 0.1715. The table preserves the calculated values before display rounding. These are calculated examples under the stated assumptions. They are not readings from a ProSense installation.

Ultrasonic echo round-trip distance. Echo pulse duration (µs) changes from 300 to 10,000 and the calculated One-way distance (m) changes from 0.05145 to 1.715.
Ultrasonic echo round-trip distance. Echo pulse duration (µs) changes from 300 to 10,000 and the calculated One-way distance (m) changes from 0.05145 to 1.715. Figure by Industry Applied.

Worked data

Echo pulse duration (µs)

One-way distance (m)

300

0.05145

600

0.1029

1000

0.1715

2000

0.343

4000

0.686

6000

1.029

10000

1.715

Checking the ends of the working range

The final interval in this example runs from 2,000 to 10,000 on the echo pulse duration (µs) axis. Its average change in one-way distance (m) per input unit is 0.000172. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 10,000 in a separate test row and compare its result against 1.715 at the displayed precision.

Installation and interpretation

Air temperature, the target angle and echoes from surrounding surfaces affect a real installation. Distinguish a missing echo from a zero distance. Confirm repeatability at known physical distances before using a level conversion.

For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.

Implementation and worked data

The source implementation is maintained in the .NET IoT device project. The component notes and manufacturer references document the supported device and its interfaces. Download the worked numerical example.