The valBut.phi trace ranges from 0.05 to 1.002 across 101 saved checkpoints. It begins at 0.05 and finishes at 1.002 after 1 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named TwoWayValves. The source file places it under Fluid, Actuators, Valves. We used the 101 stored values for valBut.phi over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name valLin (Two Way Linear), y (Ramp), sou (Boundary p T), sin (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The two named channels have separate paths in the model. valBut.phi begins at 0.05 and ends at 1.002. valLin.phi begins at 0.05 and ends at 1. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.77 to 0.78 seconds. Subtracting 0.6987 from 0.7169 gives 0.01818 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

valBut.phi (source units)

valLin.phi (source units)

0

0.05

0.05

0.2

0.1157248

0.24

0.4

0.2202362

0.43

0.6

0.4196206

0.62

0.77

0.6987295

0.7815

0.78

0.7169095

0.791

0.8

0.7531868

0.81

1

1.00204

1

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Checking the two recorded channels

At 0.78 s, valBut.phi reads 0.71691 and valLin.phi reads 0.791. Across the run, the second channel ranges from 0.05 to 1. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.