The tap1.THot.T trace covers 40 to 70 °C, a temperature span of 30 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named Tap. The source file places it under Fluid, Taps. We used the 101 stored values for tap1.THot.T over the interval 0 to 259,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name m_flow_set1 (Pulse), step (Ramp), tap1 (Tap), tap2 (Tap). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel tap1.mFloHot.y starts at 0, ends at 0 and has a recorded range of 0 to 0.1 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Two 'tap'. The simulated tap1.THot.T channel runs from 313.15 to 343.15 K over 259,200 seconds.
Two 'tap'. The simulated tap1.THot.T channel runs from 313.15 to 343.15 K over 259,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 95,904 to 98,496 seconds. Subtracting 337.448 from 335.892 gives -1.555 K. Its location brackets the change within one saved interval of 2,592 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

tap1.THot.T (K)

tap1.mFloHot.y (source units)

0

343.15

0

51840

343.15

0

95904

337.4476

0

98496

335.8924

0

103680

332.782

0

137376

313.15

0

155520

313.15

0

207360

313.15

0

259200

313.15

0

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.