The tap1.THot.T trace covers 35 to 55 °C, a temperature span of 20 K. The first recorded maximum occurs at 194,400 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named TapProfile. The source file places it under Fluid, Taps. We used the 101 stored values for tap1.THot.T over the interval 0 to 259,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name tap1 (Tap Profile), tap2 (Tap Profile), bou1 (Boundary p T), bou2 (Boundary p T). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel tap1.mFloHot.y starts at 0, ends at 0 and has a recorded range of 0 to 0.02054 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Two 'tap profile'. The simulated tap1.THot.T channel runs from 308.15 to 328.15 K over 259,200 seconds.
Two 'tap profile'. The simulated tap1.THot.T channel runs from 308.15 to 328.15 K over 259,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 41,472 to 44,064 seconds. Subtracting 319.403 from 317.522 gives -1.881 K. Its location brackets the change within one saved interval of 2,592 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

tap1.THot.T (K)

tap1.mFloHot.y (source units)

0

318.15

0

41472

319.4033

0.0001673409

44064

317.5221

0.00866

51840

312.2722

0.001566667

64800

308.15

0

103680

327.6606

0

155520

308.6394

0

194400

328.15

0.01037037

207360

324.0279

0.001341395

259200

318.15

0

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.