The recorded TFlo.port.Q_flow channel spans 69.286 to 248.226 W in this reference run. It starts at 248.226 and ends at 71.036. The first recorded maximum occurs at 0 seconds and the first minimum at 66.6 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named MixedConvection. The source file places it under Thermal Zones, Detailed, FFD, Tutorial. We used the 101 stored values for TFlo.port.Q_flow over the interval 0 to 180 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name qRadGai_flow (Constant), qConGai_flow (Constant), qLatGai_flow (Constant), TFlo (Fixed Temperature). The source declares nConExtWin = 0, nConBou = 0, nSurBou = 6, nConExt = 0. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel TOthWal[1].port.Q_flow covers -3.446 to 0.000178 W. At 0 s, the primary value is 248.226 and the companion is 0.000178. Their signed difference is 248.226 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
Integrating the signed TFlo.port.Q_flow samples by the trapezoidal rule gives 0.003893 kWh over 180 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | TFlo.port.Q_flow (W) | TOthWal[1].port.Q_flow (W) |
|---|---|---|
0 | 248.226 | 0.0001775379 |
5.4 | 248.226 | 0.0001775379 |
7.2 | 79.94496 | 0.00017533 |
36 | 71.24828 | -2.757163 |
66.6 | 69.28596 | -2.294363 |
72 | 69.28596 | -2.294363 |
108 | 72.65101 | -1.137697 |
144 | 70.57207 | -2.473741 |
180 | 71.03563 | -2.111354 |
What to check on site
Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.