The recorded tabDat_V_flow.V_flow channel spans -0.05669 to 0.02178 m³/s in this reference run. It starts at 0 and ends at -0.02033. The first recorded maximum occurs at 2,566,080 seconds and the first minimum at 1,010,880 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named TrickleVent. The source file places it under Airflow, Multizone. We used the 101 stored values for tabDat_V_flow.V_flow over the interval 0 to 2,592,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name weaDat (Reader TMY3), west (Outside Cp Low Rise), east (Outside Cp Low Rise), room (Mixing Volume). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel tabDat_m_flow.m_flow starts at 0, ends at -0.0244 and has a recorded range of -0.06803 to 0.02614 kg/s. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Trickle vent modelled using the models with flow based on tabulated data. The simulated tabDat_V_flow.V_flow channel runs from -0.05669 to 0.02178 m³/s over 2,592,000 seconds.
Trickle vent modelled using the models with flow based on tabulated data. The simulated tabDat_V_flow.V_flow channel runs from -0.05669 to 0.02178 m³/s over 2,592,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 2,592,000 seconds gives a net -9,437 m³. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

tabDat_V_flow.V_flow (m³/s)

tabDat_m_flow.m_flow (kg/s)

0

0

0

518400

-0.02310135

-0.02772174

984960

0.001960953

0.002353621

1010880

-0.0566901

-0.06802883

1036800

-0.01660814

-0.01992973

1555200

2.89388e-06

-2.411566e-06

2073600

0.00780721

0.0093681

2566080

0.02178153

0.02613809

2592000

-0.02033413

-0.02439741

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.