The recorded vent.m_flow channel spans -0.05562 to 0.02618 kg/s in this reference run. It starts at 0 and ends at -7.12e-10. The first recorded maximum occurs at 1,866,240 seconds and the first minimum at 1,010,880 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named TrickleVentIDEAS. The source file places it under Airflow, Multizone. We used the 101 stored values for vent.m_flow over the interval 0 to 2,592,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name vent (Trickle Vent), ramp (Ramp). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel tabDat_m_flow.m_flow covers -0.06803 to 0.02614 kg/s. At 2,306,880 s, the primary value is -0.01094 and the companion is -0.04688. Their signed difference is 0.03594 kg/s, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Trickle vent modelled using the models with flow based on tabulated data. The simulated vent.m_flow channel runs from -0.05562 to 0.02618 kg/s over 2,592,000 seconds.
Trickle vent modelled using the models with flow based on tabulated data. The simulated vent.m_flow channel runs from -0.05562 to 0.02618 kg/s over 2,592,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed rate over 2,592,000 seconds gives a net -4,902 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vent.m_flow (kg/s)

tabDat_m_flow.m_flow (kg/s)

0

0

0

518400

-0.02264364

-0.02772174

984960

-0.01396725

-0.01710082

1010880

-0.05562294

-0.06802883

1036800

-0.01614744

-0.01992972

1555200

0

-1.238443e-06

1866240

0.02617931

0.0261372

2073600

0.003784074

0.009368063

2592000

-7.121113e-10

-0.02439741

What to check on site

Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.