The recorded C3.C channel spans 0 to 0.002083 source units in this reference run. It starts at 0 and ends at 8.6e-05. The first recorded maximum occurs at 90 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named TraceSubstancesFlowSource. The source file places it under Fluid, Sources. We used the 101 stored values for C3.C over the interval 0 to 600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name vol (Mixing Volume), res (Pressure Drop), vol1 (Mixing Volume), assEqu (Assert Equality). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel C.C covers 0 to 0.008299 source units. At 600 s, the primary value is 8.6e-05 and the companion is 0.008299. Their signed difference is -0.008213 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Trace substances flow source. The simulated C3.C channel runs from 0 to 0.002083 source units over 600 seconds.
Trace substances flow source. The simulated C3.C channel runs from 0 to 0.002083 source units over 600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 6 seconds. Subtracting 0 from 0.00035 gives 0.00035 source units. Its location brackets the change within one saved interval of 6 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

C3.C (source units)

C.C (source units)

0

0

0

6

0.0003495234

0.008298783

90

0.002083222

0.008298783

120

0.002002819

0.008298783

240

0.001126896

0.008298783

360

0.0005043267

0.008298783

480

0.0002107935

0.008298783

600

8.595586e-05

0.008298783

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.