The recorded eff2.eta channel spans 0 to 0.4913 source units in this reference run. It starts at 0 and ends at 0. The first recorded maximum occurs at 0.58 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named TotalEfficiencyMethods. The source file places it under Fluid, Movers. We used the 101 stored values for eff2.eta over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 12 recorded variables. Alongside the primary output there are eff1.eta, eff1.etaHyd, eff1.etaMot, eff2.eta, eff2.etaHyd. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel eff2.etaHyd covers 0 to 0.7018 source units. At 0.58 s, the primary value is 0.4913 and the companion is 0.7018. Their signed difference is -0.2105 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.93 to 0.94 seconds. Subtracting 0.1309 from 0.1116 gives -0.01925 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | eff2.eta (source units) | eff2.etaHyd (source units) |
|---|---|---|
0 | 0 | 0 |
0.2 | 0.2488889 | 0.3555556 |
0.4 | 0.4251852 | 0.6074074 |
0.58 | 0.4912652 | 0.7018074 |
0.6 | 0.49 | 0.7 |
0.8 | 0.35 | 0.5 |
0.93 | 0.1308606 | 0.1869438 |
0.94 | 0.111615 | 0.15945 |
1 | 0 | 0 |
What to check on site
Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.