A 10-bit conversion placed in a 16-bit container leaves six bits unused in each stored word. The TLC1543 has eleven analogue inputs. Compare aligned storage with bit-packed transmission at the same number of conversions. In the worked example, Conversions stored 11 gives unused container bits of 66.

The recorded quantity and the calculated result

Keep three columns in a commissioning export: the original conversions stored, the configuration used in the conversion and the resulting unused container bits. Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.

Two points to check independently

At 8 the calculated unused container bits is 48. At 11 it is 66. Subtracting the first output from the second gives 18. These values give two independent checkpoints for a spreadsheet or a logger conversion.

TLC1543 multichannel data packing. Conversions stored changes from 1 to 110 and the calculated Unused container bits changes from 6 to 660.
TLC1543 multichannel data packing. Conversions stored changes from 1 to 110 and the calculated Unused container bits changes from 6 to 660. Figure by Industry Applied.

Worked data

Conversions stored

Unused container bits

1

6

4

24

8

48

11

66

22

132

44

264

110

660

Checking the ends of the working range

The interval from the middle to the upper test point runs from 11 to 110 on the conversions stored axis. Its average change in unused container bits per input unit is 6. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 110 in a separate test row and compare its result against 660 at the displayed precision.

Installation and interpretation

A word-aligned format can simplify decoding and recovery after a dropped packet. If bandwidth drives the choice, document bit order, channel order and the location of synchronization markers before defining a packed telemetry format.

For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.

Implementation and worked data

The source implementation is maintained in the .NET IoT device project. The component notes and manufacturer references document the supported device and its interfaces. Download the worked numerical example.