The recorded win.propsBus_a.surfCon.Q_flow channel spans -15.855 to 4.282 W in this reference run. It starts at 0 and ends at 0.3105. The first recorded maximum occurs at 150,000 seconds and the first minimum at 130,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named WindowThermalBridge. The source file places it under Buildings, Components. We used the 101 stored values for win.propsBus_a.surfCon.Q_flow over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name bou (Boundary p T), floor (Outer Wall), zone (Zone), win (Window). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel winLinLos.propsBus_a.surfCon.Q_flow covers -19.385 to 6.02 W. At 130,000 s, the primary value is -15.855 and the companion is -19.385. Their signed difference is 3.53 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Three window thermal bridge options. The simulated win.propsBus_a.surfCon.Q_flow channel runs from -15.855 to 4.282 W over 1,000,000 seconds.
Three window thermal bridge options. The simulated win.propsBus_a.surfCon.Q_flow channel runs from -15.855 to 4.282 W over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed win.propsBus_a.surfCon.Q_flow samples by the trapezoidal rule gives 0.006325 kWh over 1,000,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

win.propsBus_a.surfCon.Q_flow (W)

winLinLos.propsBus_a.surfCon.Q_flow (W)

0

0

0

120000

-1.349356

-1.34926

130000

-15.85527

-19.38528

150000

4.28236

6.019598

200000

2.104735

3.268351

400000

-0.08668616

0.1746354

600000

0.04444348

0.05294896

800000

2.001978

3.143967

1000000

0.3104977

0.4985191

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.