The recorded windowTwo.propsBus_a.surfCon.Q_flow channel spans -138.91 to 47.744 W in this reference run. It starts at 0 and ends at 3.034. The first recorded maximum occurs at 150,000 seconds and the first minimum at 130,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named WindowDynamics. The source file places it under Buildings, Components. We used the 101 stored values for windowTwo.propsBus_a.surfCon.Q_flow over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name bou (Boundary p T), windowTwo (Window), windowNone (Window), windowNormal (Window). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel windowNone.propsBus_a.surfCon.Q_flow covers -151.424 to 52.386 W. At 120,000 s, the primary value is -26.371 and the companion is -45.215. Their signed difference is 18.843 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Three window dynamics options. The simulated windowTwo.propsBus_a.surfCon.Q_flow channel runs from -138.91 to 47.744 W over 1,000,000 seconds.
Three window dynamics options. The simulated windowTwo.propsBus_a.surfCon.Q_flow channel runs from -138.91 to 47.744 W over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed windowTwo.propsBus_a.surfCon.Q_flow samples by the trapezoidal rule gives -1.003 kWh over 1,000,000 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

windowTwo.propsBus_a.surfCon.Q_flow (W)

windowNone.propsBus_a.surfCon.Q_flow (W)

0

0

7.451459

130000

-138.9101

-151.4237

150000

47.74417

52.38627

200000

9.217639

9.723097

400000

-3.281191

-0.01386054

600000

0.2448358

0.2087439

740000

-105.7378

-110.4468

750000

25.89041

41.42023

800000

10.41373

11.12737

1000000

3.033967

3.795529

What to check on site

Keep the occupied schedule, weather boundary and zone definition with the result. A change in a simulated room condition can reflect the boundary assumptions as well as the component under study. Compare occupied periods and maintain the same observation location.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.