The temperature.T trace covers 11.228 to 58.772 °C, a temperature span of 47.543 K. The first recorded maximum occurs at 2 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
The KU Leuven IDEAS project publishes the IDEAS test named ThreeWayValveMotor. The source file places it under Fluid, Actuators, Valves, Simplified. We used the 101 stored values for temperature.T over the interval 0 to 100 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 3 recorded variables. Alongside the primary output there are temperature.T, cold.T, hot.T. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The primary channel spends 39.6% of its saved checkpoints at or above 308.15 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 308.15 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 54 to 55 seconds. Subtracting 322.842 from 308.15 gives -14.692 K. Its location brackets the change within one saved interval of 1 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | temperature.T (K) |
|---|---|
0 | 308.15 |
2 | 331.9217 |
7 | 284.3784 |
20 | 308.15 |
40 | 308.15 |
54 | 322.8417 |
55 | 308.15 |
60 | 308.15 |
80 | 308.15 |
100 | 308.15 |
What to check on site
Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.