The recorded dooAB.vAB channel spans 0 to 0.08841 source units in this reference run. It starts at 0 and ends at 0.000758. The first recorded maximum occurs at 6,336 seconds and the first minimum at 0 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named ClosedDoors. The source file places it under Airflow, Multizone. We used the 101 stored values for dooAB.vAB over the interval 0 to 7,200 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name dooAB (Door Discretized Operable), volA (Mixing Volume), volB (Mixing Volume), preHeaFlo (Prescribed Heat Flow). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel dooAB.vBA covers 0 to 0.08853 source units. At 864 s, the primary value is 0 and the companion is 0.08853. Their signed difference is -0.08853 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 3,456 to 3,528 seconds. Subtracting 0.02242 from 0.01105 gives -0.01137 source units. Its location brackets the change within one saved interval of 72 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | dooAB.vAB (source units) | dooAB.vBA (source units) |
|---|---|---|
0 | 0 | 0 |
1440 | 0.01731009 | 0.06933495 |
2880 | 0.08427906 | 0 |
3456 | 0.02241581 | 0 |
3528 | 0.0110505 | 0 |
4320 | 0 | 0.08462143 |
5760 | 0.06918655 | 0.01717944 |
6336 | 0.08841062 | 0 |
7200 | 0.0007580212 | 0.0007579784 |
What to check on site
Identify the connected zones, pressure references and flow direction. Changing a door, leakage path or boundary condition can redistribute the same total flow between branches. A differential pressure alone cannot establish the air quantity reaching a zone.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.