Use already scaled axis measurements. Fix the illustrative X component at 0.8 g and Z at zero, then vary Y. The vector magnitude is the square root of the sum of the three squared components. Both sign and orientation remain in the original axis channels. With y-axis component (g) at 0.6, the worked result is 1 on the resultant with a fixed 0.8 g x component (g) scale.
The recorded quantity and the calculated result
Keep three columns in a commissioning export: the original y-axis component (g), the configuration used in the conversion and the resulting resultant with a fixed 0.8 g x component (g). Recompute the result for the lower, middle and upper worked points before interpreting a field difference. A change in range, units or representation can otherwise be mistaken for a change in the process.
Two points to check independently
Take the neighbouring worked points 0.4 and 0.6 on the input axis. The results are 0.8944 and 1, giving a signed difference of 0.1056. The table preserves the calculated values before display rounding. These are calculated examples under the stated assumptions. They are not readings from a ProSense installation.

Worked data
Y-axis component (g) | Resultant with a fixed 0.8 g X component (g) |
|---|---|
0 | 0.8 |
0.2 | 0.8246211 |
0.4 | 0.8944272 |
0.6 | 1 |
0.8 | 1.131371 |
1 | 1.280625 |
1.2 | 1.442221 |
Checking the ends of the working range
The final interval in this example runs from 0.6 to 1.2 on the y-axis component (g) axis. Its average change in resultant with a fixed 0.8 g x component (g) per input unit is 0.737. This is a two-point slope for that interval. To check a spreadsheet or a gateway calculation, enter 1.2 in a separate test row and compare its result against 1.442 at the displayed precision.
Installation and interpretation
A single axis can change as a stationary sensor tilts in gravity. The magnitude helps distinguish redistribution among axes from an increase in total acceleration. For moving machinery, gravity, vibration and other motion can all contribute.
For a repeatable verification, capture a small known case and a second case well away from it. Check whether the difference follows the response in the table, then restore the working configuration and repeat one reading. Store a separate status field for missing or invalid input. Substituting zero would make a dropped observation indistinguishable from a legitimate numerical zero.
Implementation and worked data
The source implementation is maintained in the .NET IoT device project. The component notes and manufacturer references document the supported device and its interfaces. Download the worked numerical example.