The T_out.T trace covers 20 to 30.01 °C, a temperature span of 10.01 K. The first recorded maximum occurs at 18.2 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named Thermostatic3WayValve. The source file places it under Fluid, Actuators, Valves, Simplified. We used the 101 stored values for T_out.T over the interval 0 to 20 seconds. This is a simulated test with specified inputs and boundaries.

The source declares m_flow_nominal = 2. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel sou1.T_in starts at 283.15, ends at 313.15 and has a recorded range of 283.15 to 313.15 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Thermostatic three-way valve. The simulated T_out.T channel runs from 293.15 to 303.16 K over 20 seconds.
Thermostatic three-way valve. The simulated T_out.T channel runs from 293.15 to 303.16 K over 20 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 6.4 to 6.6 seconds. Subtracting 299.492 from 300.09 gives 0.5982 K. Its location brackets the change within one saved interval of 0.2 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

T_out.T (K)

sou1.T_in (source units)

0

293.15

283.15

4

293.6843

295.15

6.4

299.4918

302.35

6.6

300.09

302.95

8

302.4209

307.15

12

303.1471

313.15

16

303.16

313.15

18.2

303.1603

313.15

20

303.1602

313.15

What to check on site

Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.