The published valDyn.m_flow signal spans 2.665e-08 to 0.034 kg/s in the reference run. It starts at 0.034 and finishes at 2.689e-08. The signed change between those endpoint samples is -0.034 kg/s.
What the reference test measures
The IDEAS model named TwoWayValveTRV comes from the KU Leuven IDEAS project. The saved result covers simulation time 0 to 7,200 seconds. Industry Applied extracted 101 checkpoints for valDyn.m_flow and kept the original signed values. The regular output spacing is 72 seconds. The solver may take different internal steps.
The model definition identifies valSte (Two Way TRV), valDyn (Two Way TRV), sou (Boundary p T). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares sou.T = 293.15, sin.T = 293.15, valSte.m_flow_nominal = 0.03. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 4,320 seconds, valDyn.m_flow is 0.017 and valSte.m_flow is 0.017. Subtracting the second channel from the first gives +2.643e-05 kg/s, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Reproducing the largest recorded change
Between the stored points at 4,320 and 4,392 seconds, valDyn.m_flow changes from 0.017 to 0.015. Subtracting the earlier reading gives -0.001585 kg/s. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | valDyn.m_flow (kg/s) | valSte.m_flow (kg/s) |
|---|---|---|
0 | 0.03387052 | 0.03387052 |
1800 | 0.03387052 | 0.03387052 |
3600 | 0.03037986 | 0.03036475 |
4320 | 0.01696338 | 0.01693696 |
4392 | 0.01537841 | 0.01535208 |
5400 | 0.0005503379 | 0.0005447157 |
5904 | 2.665234e-08 | 2.688779e-08 |
7200 | 2.688779e-08 | 2.688779e-08 |
Applying the result to an operating site
A thermostatic head has a sensing element and feedback delay. Flow can still move with circuit pressure while the valve position is catching up. Observe room conditions, return flow and differential pressure together before attributing a transient to the head.
For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.
Model and data sources
Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.