The archived response ranges from 14.13 to 851.61. The median is 273.56 and the central half of the measurements extends from 120.095 to 484.832. Those figures use all 236 numeric observations in this source series and retain its original measurement scale.

What was measured

The HAHN1 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as coefficient of thermal expansion. It preserves the source scale and its sign. The file contains 2 numeric fields per accepted row.

Spread across the original readings

The tenth percentile is 46.95 and the ninetieth is 644.125. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 837.48. This is the range of this sample, rather than a guaranteed operating envelope.

Thermal expansion of a reference material. The 25th, 50th and 75th percentiles of the measurements are 120.095, 273.56 and 484.832.
Thermal expansion of a reference material. The 25th, 50th and 75th percentiles of the measurements are 120.095, 273.56 and 484.832. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 91 after the header. Its response is 273.66. The overall arithmetic mean is 321.297, so this observation is -47.637 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 364.737, calculated by subtracting 120.095 from 484.832.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

14.13

236

10

46.95

236

25

120.095

236

50

273.56

236

75

484.8325

236

90

644.125

236

100

851.61

236

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data