The recorded Case900SolBus.building.TSensor[1] channel spans 293.134 to 295.444 source units in this reference run. It starts at 293.15 and ends at 293.139. The first recorded maximum occurs at 140,000 seconds and the first minimum at 890,000 seconds.

The system being tested

The KU Leuven IDEAS project publishes the IDEAS test named SolarBusValidation. The source file places it under Buildings, Tests. We used the 101 stored values for Case900SolBus.building.TSensor[1] over the interval 0 to 1,000,000 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 2 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The primary channel spends 2.0% of its saved checkpoints at or above 294.289 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 293.2 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Tests solar bus. The simulated Case900SolBus.building.TSensor[1] channel runs from 293.134 to 295.444 source units over 1,000,000 seconds.
Tests solar bus. The simulated Case900SolBus.building.TSensor[1] channel runs from 293.134 to 295.444 source units over 1,000,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 130,000 to 140,000 seconds. Subtracting 293.161 from 295.444 gives 2.282 source units. Its location brackets the change within one saved interval of 10,000 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

Case900SolBus.building.TSensor[1] (source units)

0

293.15

130000

293.1611

140000

295.4436

200000

293.1387

400000

293.1409

600000

293.1383

800000

293.1375

890000

293.1342

1000000

293.139

What to check on site

Check the time reference, location and receiving plane for each environmental input. Two measured series can differ because one records horizontal exposure and the other a tilted surface. A comparison needs the same averaging interval and geometric definition.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model