The recorded voltageControl.y channel spans -1.85e-07 to 1 source units in this reference run. It starts at 1 and ends at 1. The first recorded maximum occurs at 5.2 seconds and the first minimum at 1.3 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named TestVoltageCTRL. The source file places it under Electrical, Utilities. We used the 101 stored values for voltageControl.y over the interval 0 to 10 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name voltageControl (Voltage Control), sou (Voltage Source), cosine (Sine), Vtr_high (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel sou.V_in starts at 120, ends at 120 and has a recorded range of 100 to 140 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Test voltage ctrl. The simulated voltageControl.y channel runs from -1.85e-07 to 1 source units over 10 seconds.
Test voltage ctrl. The simulated voltageControl.y channel runs from -1.85e-07 to 1 source units over 10 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1 to 1.1 seconds. Subtracting 1 from 0.000527 gives -0.9995 source units. Its location brackets the change within one saved interval of 0.1 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

voltageControl.y (source units)

sou.V_in (source units)

0

1

120

1

1

131.7557

1.1

0.0005271652

132.7485

1.3

-1.853874e-07

134.5794

2

-1.270427e-09

139.0211

4

1.203147e-12

131.7557

5.2

1.000003

117.4933

6

1

108.2443

8

1

100.9789

10

1

120

What to check on site

Keep voltage, current, real power and energy distinct. Establish the reference direction at the measurement terminal before interpreting a sign change as import or export. Compare the same load boundary and duration in site data and the simulation.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.