The recorded combiTimeTable.y[1] channel spans 367.916 to 376.7 source units in this reference run. It starts at 372.3 and ends at 373. The first recorded maximum occurs at 84,546 seconds and the first minimum at 591,822 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named TestData. The source file places it under Fluid, Fixed Resistances, Plug Flow Pipes, Data. We used the 101 stored values for combiTimeTable.y[1] over the interval 0 to 603,900 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 1 recorded variables. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The primary channel spends 53.5% of its saved checkpoints at or above 372.308 source units, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 372.613 source units. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.
![Test data. The simulated combiTimeTable.y[1] channel runs from 367.916 to 376.7 source units over 603,900 seconds.](https://static.wixstatic.com/media/21e41b_47381ee79c13440b9b7d01bea3e0e378~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_47381ee79c13440b9b7d01bea3e0e378~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 531,432 to 537,471 seconds. Subtracting 375.652 from 371.985 gives -3.667 source units. Its location brackets the change within one saved interval of 6,039 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | combiTimeTable.y[1] (source units) |
|---|---|
0 | 372.3 |
84546 | 376.7 |
120780 | 370.92 |
241560 | 371.66 |
362340 | 373.58 |
483120 | 370.98 |
531432 | 375.652 |
537471 | 371.985 |
591822 | 367.916 |
603900 | 373 |
What to check on site
Distinguish the component characteristic from the installed system response. Record the pressure or temperature on both sides as applicable, the direction of flow and the actuator command. Compare a change at constant demand with one caused by a different load.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.