The temperature inside a stratified store starts at 20 °C and finishes at 56.845 °C in this reference run. The model stores absolute temperature in kelvin. Its observed minimum and maximum convert to 20 °C and 56.845 °C.
What the reference test measures
The Buildings model named StratifiedEnhancedInternalHex comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 1,200 seconds. Industry Applied extracted 101 checkpoints for tanDynSol.vol[3].T and kept the original signed values. The regular output spacing is 12 seconds. The solver may take different internal steps.
The model definition identifies tanDyn (Stratified Enhanced Internal Hex), tanDynSol (Stratified Enhanced Internal Hex), bouWat (Boundary p T). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.
Settings to preserve when repeating the experiment
The published test declares solColSup.T = 353.15, toSolCol.T = 283.15, tanSte.m_flow_nominal = 0.001. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.
Reading the two channels
At 312 seconds, tanDynSol.vol[3].T is 294.035 and tanDyn.vol[3].T is 293.999. Subtracting the second channel from the first gives +0.036 K, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.
![Temperature inside a stratified store. In the simulated StratifiedEnhancedInternalHex case, tanDynSol.vol[3].T ranges from 293.15 to 329.995 K over 1,200 seconds.](https://static.wixstatic.com/media/21e41b_29153fd758a3463f960643650edb15d1~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_29153fd758a3463f960643650edb15d1~mv2.png)
Reproducing the largest recorded change
Between the stored points at 300 and 312 seconds, tanDynSol.vol[3].T changes from 293.15 to 294.035. Subtracting the earlier reading gives +0.885 K. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.
The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.
Worked data
Simulation time (s) | tanDynSol.vol[3].T (K) | tanDyn.vol[3].T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
300 | 293.15 | 293.15 |
312 | 294.0351 | 293.9992 |
600 | 309.5078 | 309.4861 |
900 | 321.3998 | 321.3823 |
1200 | 329.9953 | 329.9815 |
Applying the result to an operating site
One tank sensor represents a layer and a mounting location. A top reading can mask a cooler region below the heat exchanger. Use the vertical temperature profile, flow direction and exchanger position when interpreting stored usable heat.
For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.
Model and data sources
Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.