The temperature inside a stratified store starts at 20 °C and finishes at 56.845 °C in this reference run. The model stores absolute temperature in kelvin. Its observed minimum and maximum convert to 20 °C and 56.845 °C.

What the reference test measures

The Buildings model named StratifiedEnhancedInternalHex comes from Lawrence Berkeley National Laboratory. The saved result covers simulation time 0 to 1,200 seconds. Industry Applied extracted 101 checkpoints for tanDynSol.vol[3].T and kept the original signed values. The regular output spacing is 12 seconds. The solver may take different internal steps.

The model definition identifies tanDyn (Stratified Enhanced Internal Hex), tanDynSol (Stratified Enhanced Internal Hex), bouWat (Boundary p T). These component names let a reader trace the plotted tags to their owning blocks before reproducing the result.

Settings to preserve when repeating the experiment

The published test declares solColSup.T = 353.15, toSolCol.T = 283.15, tanSte.m_flow_nominal = 0.001. Those numbers use the units and component definitions in the linked model. Start with the declared configuration when reproducing the reference result, then vary one setting at a time. Changing the input waveform and the component response in the same comparison makes it difficult to identify the source of a difference.

Reading the two channels

At 312 seconds, tanDynSol.vol[3].T is 294.035 and tanDyn.vol[3].T is 293.999. Subtracting the second channel from the first gives +0.036 K, the largest absolute separation on their common saved grid. The channels have distinct roles in the model, so this difference describes the two traces and is not a calibrated instrument error.

Temperature inside a stratified store. In the simulated StratifiedEnhancedInternalHex case, tanDynSol.vol[3].T ranges from 293.15 to 329.995 K over 1,200 seconds.
Temperature inside a stratified store. In the simulated StratifiedEnhancedInternalHex case, tanDynSol.vol[3].T ranges from 293.15 to 329.995 K over 1,200 seconds. Figure by Industry Applied.

Reproducing the largest recorded change

Between the stored points at 300 and 312 seconds, tanDynSol.vol[3].T changes from 293.15 to 294.035. Subtracting the earlier reading gives +0.885 K. This interval contains the largest absolute point-to-point change in the saved primary channel. A faster excursion followed by recovery could fit entirely between the two records.

The extrema in the table and figure are extrema of the stored series. A solver’s internal peak, a field logger’s alarm value and a maximum derived from this export can differ. Preserve the sampling settings when comparing results.

Worked data

Simulation time (s)

tanDynSol.vol[3].T (K)

tanDyn.vol[3].T (K)

0

293.15

293.15

300

293.15

293.15

312

294.0351

293.9992

600

309.5078

309.4861

900

321.3998

321.3823

1200

329.9953

329.9815

Applying the result to an operating site

One tank sensor represents a layer and a mounting location. A top reading can mask a cooler region below the heat exchanger. Use the vertical temperature profile, flow direction and exchanger position when interpreting stored usable heat.

For a local engineering comparison, write the measurement boundary, operating duty and instruments into the test record. Select comparable load or weather periods, then compare the measured trace with the simulated quantities. Establish a local acceptance tolerance using the intended duty and measurement uncertainty.

Model and data sources

Model definition. Original numerical reference series. Simulation and plotting script. Source project. Download the worked checkpoints as CSV.

Cover photograph by Daniel Dan, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.