The recorded TBouPul.port.T temperature spans 12.713 °C to 20 °C in this simulation. That is a change of 7.2873 K. The first saved maximum occurs at 0 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SingleUTubeBoundaryCondition. The source file places it under Fluid, Geothermal, Boreholes. We used the 101 stored values for TBouPul.port.T over the interval 0 to 157,680,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TBouSte (Single U Tube Boundary Condition), TBouCon (Single U Tube Boundary Condition), TBouPul (Single U Tube Boundary Condition). The source declares Q_flow = -50. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The primary channel spends 7.9% of its saved checkpoints at or above 289.506 K, halfway between the observed minimum and maximum. Its time-weighted mean under piecewise-linear interpolation is 287.264 K. These two numbers distinguish how much of the run is spent high from the absolute value of its peak.

Temperature boundary condition of a single u tube heat exchanger. The simulated TBouPul.port.T channel runs from 285.863 to 293.15 K over 157,680,000 seconds.
Temperature boundary condition of a single u tube heat exchanger. The simulated TBouPul.port.T channel runs from 285.863 to 293.15 K over 157,680,000 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,576,800 to 3,153,600 seconds. Subtracting 292.228 from 291.246 gives -0.9826 K. Its location brackets the change within one saved interval of 1,576,800 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TBouPul.port.T (K)

0

293.15

1576800

292.2285

3153600

291.2458

3.1536e+07

288.1308

6.3072e+07

287.1577

9.4608e+07

286.5854

1.26144e+08

286.1786

1.5768e+08

285.8627

What to check on site

The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.