The recorded tanSta.TTan[1] channel spans 279.65 to 282.15 source units in this reference run. It starts at 282.15 and ends at 282.15. The first recorded maximum occurs at 0 seconds and the first minimum at 0.25 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named TankStatus. The source file places it under DHC, Plants, Cooling, Controls. We used the 101 stored values for tanSta.TTan[1] over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name tanSta (Tank Status). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel tanSta.TTan[2] covers 284.15 to 286.65 source units. At 0.25 s, the primary value is 279.65 and the companion is 286.65. Their signed difference is -7 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
![Tank status controller. The simulated tanSta.TTan[1] channel runs from 279.65 to 282.15 source units over 1 seconds.](https://static.wixstatic.com/media/21e41b_ca58420f6a524cb29d17d1380d4f3384~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_ca58420f6a524cb29d17d1380d4f3384~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0.97 to 0.98 seconds. Subtracting 281.85 from 281.95 gives 0.1 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | tanSta.TTan[1] (source units) | tanSta.TTan[2] (source units) |
|---|---|---|
0 | 282.15 | 284.15 |
0.2 | 280.15 | 286.15 |
0.25 | 279.65 | 286.65 |
0.4 | 280.25 | 286.05 |
0.6 | 280.25 | 286.05 |
0.8 | 280.15 | 286.15 |
0.97 | 281.85 | 284.45 |
0.98 | 281.95 | 284.35 |
1 | 282.15 | 284.15 |
What to check on site
Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
![Tank status controller. Range and median of consecutive groups of recorded samples. tanSta.TTan[1] (source units). 0.04 to 0.97.](/story-art/13d50a63d999e49ed.webp)