The tan.sta_b.T trace covers 20 to 29.998 °C, a temperature span of 9.998 K. The first recorded maximum occurs at 500 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Tanks. The source file places it under Templates, Components. We used the 101 stored values for tan.sta_b.T over the interval 0 to 500 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sou (Mass Flow Source T), tan (Buffer), sin (Boundary p T), senVolFlo (Volume Flow Rate). The source declares m_flow_nominal = 1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel intFlo.y starts at 0, ends at 0.5022 and has a recorded range of 0 to 0.5022 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Tank components. The simulated tan.sta_b.T channel runs from 293.15 to 303.148 K over 500 seconds.
Tank components. The simulated tan.sta_b.T channel runs from 293.15 to 303.148 K over 500 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 5 seconds. Subtracting 293.15 from 293.95 gives 0.7996 K. Its location brackets the change within one saved interval of 5 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

tan.sta_b.T (K)

intFlo.y (source units)

0

293.15

0

5

293.9496

0.005022168

100

301.2613

0.1004434

200

302.7932

0.2008867

300

303.0826

0.3013301

400

303.1372

0.4017734

500

303.1476

0.5022168

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.