The recorded hpSupLvg.Q_flow channel spans 0 to 889,828 W in this reference run. It starts at 0 and ends at 889,828. The first recorded maximum occurs at 90 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named TableData2DLoadDep. The source file places it under Fluid, Heat Pumps, Modular Reversible, Refrigerant Cycle. We used the 101 stored values for hpSupLvg.Q_flow over the interval 0 to 100 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name TChiWatSet (Ramp), THeaWatSet (Ramp), TConEnt (Constant), TConLvg (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel chiRetEnt.Q_flow covers -630,369 to 0 W. At 90 s, the primary value is 889,828 and the companion is -630,369. Their signed difference is 1,520,197 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Table data2 d load dep. The simulated hpSupLvg.Q_flow channel runs from 0 to 889,828 W over 100 seconds.
Table data2 d load dep. The simulated hpSupLvg.Q_flow channel runs from 0 to 889,828 W over 100 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed hpSupLvg.Q_flow samples by the trapezoidal rule gives 12.359 kWh over 100 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hpSupLvg.Q_flow (W)

chiRetEnt.Q_flow (W)

0

0

0

20

111228.5

-78796.12

37

300316.9

-212749.5

38

311439.8

-220629.2

40

333685.5

-236388.4

60

556142.5

-393980.6

80

778599.5

-551572.9

90

889828

-630369

100

889828

-630369

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.

Cover photograph by Jakub Zerdzicki, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.