The recorded wetBulPhi.TWetBul temperature spans 10.263 °C to 29.4 °C in this simulation. That is a change of 19.137 K. The first saved maximum occurs at 1 s. The source trace and download retain absolute temperatures in kelvin.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named TWetBul_TDryBulPhi. The source file places it under Utilities, Psychrometrics. We used the 101 stored values for wetBulPhi.TWetBul over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name wetBulPhi (T Wet Bul T Dry Bul Phi), p (Constant), phi (Ramp), TDryBul (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

At 0.03 s, wetBulPhi.TWetBul is 284.23 K and wetBulPhiApp.TWetBul is 282.975 K. Subtracting the second value from the first gives 1.255 K. This is their largest recorded absolute separation. A difference between an inlet and an outlet, or between a command and a response, need not be a measurement error.

T wet bul t dry bul phi. The simulated wetBulPhi.TWetBul channel runs from 283.413 to 302.55 K over 1 seconds.
T wet bul t dry bul phi. The simulated wetBulPhi.TWetBul channel runs from 283.413 to 302.55 K over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 0.01 seconds. Subtracting 283.413 from 283.688 gives 0.2748 K. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

wetBulPhi.TWetBul (K)

wetBulPhiApp.TWetBul (K)

0

283.4127

283.1759

0.01

283.6875

283.3644

0.2

288.4675

288.6422

0.4

292.7467

293.1114

0.6

296.4376

296.6064

0.8

299.6735

299.7037

1

302.55

302.6267

What to check on site

Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.