The recorded TOut.y channel spans 273.363 to 297.149 source units in this reference run. It starts at 285.15 and ends at 273.363. The first recorded maximum occurs at 2,520 seconds and the first minimum at 7,200 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Enable. The source file places it under Templates, Plants, Controls, Enabling. We used the 101 stored values for TOut.y over the interval 0 to 7,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name enaHea (Enable), req (Pulse), TOut (Sin), enaCoo (Enable). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel req.y covers 1 to 2 source units. At 2,376 s, the primary value is 297.114 and the companion is 1. Their signed difference is 296.114 source units, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

System enabling logic. The simulated TOut.y channel runs from 273.363 to 297.149 source units over 7,200 seconds.
System enabling logic. The simulated TOut.y channel runs from 273.363 to 297.149 source units over 7,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 4,968 to 5,040 seconds. Subtracting 285.391 from 284.848 gives -0.5428 source units. Its location brackets the change within one saved interval of 72 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

TOut.y (source units)

req.y (source units)

0

285.15

2

1440

294.5854

2

2520

297.149

2

2880

296.8096

2

4320

290.1225

1

4968

285.3913

2

5040

284.8484

2

5760

279.635

1

7200

273.3625

1

What to check on site

Record each condition, calculated request and issued output as separate tags. Keep timestamps and the sample or event rule with the export. A stable displayed value may be held by logic after the measured input has changed.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.