The lowest observed group mean is -10.515 for data Set group 102 to 403. The highest is -1.978 for group 603 to 702, a difference of 8.538 on the source response scale. Across all 4,744 numeric records the response median is -4.644.

What was measured

The BENNETT6 data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as magnetism M. It preserves the source scale and its sign. The file contains 4 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 1,791 and 721 observations. Their medians are -9.523 and -2.01, respectively. The figure groups the original entries by the recorded data Set value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Superconducting magnetisation. The lowest and highest group means are -10.515 and -1.978 on the source response scale.
Superconducting magnetisation. The lowest and highest group means are -10.515 and -1.978 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 3,086 after the header. Its response is -4.644. The overall arithmetic mean is -6.11, so this observation is 1.466 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 3.133, calculated by subtracting -5.984 from -2.851.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

data Set group

Observations

Mean response

Median response

Minimum response

Maximum response

102 to 403

1791

-10.51543

-9.52331

-34.8347

-5.58702

453 to 453

744

-4.782767

-4.72111

-6.02287

-4.59947

503 to 553

1488

-3.47405

-3.797995

-5.0362

-2.7388

603 to 702

721

-1.977648

-2.00987

-2.60254

-1.11175

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.

Cover photograph by RDNE Stock project, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.