The lowest observed group mean is -32.855 for experiment group 2. The highest is 238.912 for group 6, a difference of 271.767 on the source response scale. Across all 920 numeric records the response median is 95.
What was measured
The DORKO17 data file has 50 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as sO2 Concentration. It preserves the source scale and its sign. The file contains 9 numeric fields per accepted row.
Spread across the original readings
The two endpoint groups have 200 and 80 observations. Their medians are 55.5 and 95, respectively. The figure groups the original entries by the recorded experiment value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

One row you can check
To check a real observation, take numeric row 875 after the header. Its response is 95. The overall arithmetic mean is 140.634, so this observation is -45.634 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 252, calculated by subtracting 30 from 282.
The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.
Worked data
experiment group | Observations | Mean response | Median response | Minimum response | Maximum response |
|---|---|---|---|---|---|
1 | 200 | 125.525 | 64 | -900 | 538 |
2 | 200 | -32.855 | 55.5 | -900 | 640 |
3 | 160 | 214.9938 | 157.5 | -900 | 729 |
4 | 160 | 208.6813 | 146 | -95 | 763 |
5 | 120 | 199.5667 | 127 | 0 | 785 |
6 | 80 | 238.9125 | 95 | -700 | 3611 |
Implications for an industrial comparison
A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.
Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.
Source file and worked data
The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.
Cover photograph by RDNE Stock project, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.