The recorded floMacDyn.dpMachine channel spans 0 to 33,061 Pa in this reference run. It starts at 33,061 and ends at 0. The first recorded maximum occurs at 0 seconds and the first minimum at 0.75 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named Pump_stratos. The source file places it under Fluid, Movers. We used the 101 stored values for floMacDyn.dpMachine over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The reference file contains 5 recorded variables. Alongside the primary output there are gain.u, floMacDyn.dpMachine, floMacSta.dpMachine, floMacSta.VMachine_flow, floMacDyn.VMachine_flow. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.

Compare the recorded channels

The companion channel floMacSta.dpMachine covers 0 to 33,061 Pa. At 0.75 s, the primary value is 0 and the companion is 0. Their signed difference is 0 Pa, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Stratos pumps with speed as input. The simulated floMacDyn.dpMachine channel runs from 0 to 33,061 Pa over 1 seconds.
Stratos pumps with speed as input. The simulated floMacDyn.dpMachine channel runs from 0 to 33,061 Pa over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.25 to 0.26 seconds. Subtracting 33,061 from 31,752 gives -1,309 Pa. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

floMacDyn.dpMachine (Pa)

floMacSta.dpMachine (Pa)

0

33061.02

33061.02

0.2

33061.02

33061.02

0.25

33061.02

33061.02

0.26

31751.75

31751.75

0.4

16199.37

16199.37

0.6

2974.965

2974.965

0.75

0

0

0.8

0

0

1

0

0

What to check on site

Mark the measurement points on a hydraulic schematic and identify whether the controller holds flow or differential pressure. Record pump command and delivered duty together. A site comparison needs the same branch state, including bypasses and closed valves.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model