The senTem.T trace covers 37.272 to 80 °C, a temperature span of 42.728 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named StratifiedUnloadAtMinimumTemperature. The source file places it under Fluid, Storage. We used the 101 stored values for senTem.T over the interval 0 to 21,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name tan (Stratified), loa (Boundary p T), masSou (Mass Flow Source T), valTop (Two Way Linear). The source declares VTan = 3, m_flow_nominal = 3*1000/3600. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel tan.vol[1].T covers 310.422 to 353.15 K. At 2,592 s, the primary value is 315.327 and the companion is 353.144. Their signed difference is -37.816 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Stratified unload at minimum temperature. The simulated senTem.T channel runs from 310.422 to 353.15 K over 21,600 seconds.
Stratified unload at minimum temperature. The simulated senTem.T channel runs from 310.422 to 353.15 K over 21,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 2,592 to 2,808 seconds. Subtracting 315.327 from 352.842 gives 37.515 K. Its location brackets the change within one saved interval of 216 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

senTem.T (K)

tan.vol[1].T (K)

0

353.15

353.15

2592

315.3275

353.1436

2808

352.8421

352.8422

4320

320.915

320.915

5400

310.4219

310.4219

8640

321.5329

323.3091

12960

322.0992

323.3091

17280

322.5681

323.3091

21600

322.9315

323.3089

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.