The cooTan.vol[1].T trace covers 20.021 to 40 °C, a temperature span of 19.979 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named StratifiedNonUniformInitial. The source file places it under Fluid, Storage. We used the 101 stored values for cooTan.vol[1].T over the interval 0 to 3,600 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sin_1 (Mass Flow Source T), heaTan (Stratified), sin_2 (Mass Flow Source T), cooTan (Stratified). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel cooTan.vol[2].T covers 293.157 to 312.15 K. At 1,152 s, the primary value is 303.618 and the companion is 300.892. Their signed difference is 2.725 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Stratified tank with non-uniform initial temperature. The simulated cooTan.vol[1].T channel runs from 293.171 to 313.15 K over 3,600 seconds.
Stratified tank with non-uniform initial temperature. The simulated cooTan.vol[1].T channel runs from 293.171 to 313.15 K over 3,600 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 1,116 to 1,152 seconds. Subtracting 304.097 from 303.618 gives -0.4794 K. Its location brackets the change within one saved interval of 36 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

cooTan.vol[1].T (K)

cooTan.vol[2].T (K)

0

313.15

312.15

720

308.8086

306.8634

1116

304.0973

301.3742

1152

303.6179

300.8924

1440

299.9647

297.5945

2160

294.6209

293.8691

2880

293.3509

293.2278

3600

293.1707

293.1567

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.