The domHotWatTan.TTanBot.T trace covers 39.081 to 50 °C, a temperature span of 10.919 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named StorageTankWithExternalHeatExchanger. The source file places it under DHC, Loads, Hot Water. We used the 101 stored values for domHotWatTan.TTanBot.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sch (Combi Time Table), souCol (Boundary p T), conTSetMix (Constant), domHotWatTan (Storage Tank With External Heat Exchanger). The source declares TCol = 273.15+10. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel theMixVal.senTMix.T covers 293.15 to 308.15 K. At 0 s, the primary value is 323.15 and the companion is 293.15. Their signed difference is 30 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Storage tank with external heat exchanger. The simulated domHotWatTan.TTanBot.T channel runs from 312.231 to 323.15 K over 172,800 seconds.
Storage tank with external heat exchanger. The simulated domHotWatTan.TTanBot.T channel runs from 312.231 to 323.15 K over 172,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 22,464 to 24,192 seconds. Subtracting 318.741 from 316.879 gives -1.862 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

domHotWatTan.TTanBot.T (K)

theMixVal.senTMix.T (K)

0

323.15

293.15

22464

318.7408

308.15

24192

316.8792

308.15

34560

312.6635

308.15

69120

313.0442

308.15

103680

319.4791

308.15

112320

312.2307

308.15

138240

319.572

308.15

172800

320.1752

308.15

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.