The tanEnh.vol[1].T trace covers 20 to 33.912 °C, a temperature span of 13.912 K. The first recorded maximum occurs at 3,564 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named Stratified. The source file places it under Fluid, Storage. We used the 101 stored values for tanEnh.vol[1].T over the interval 0 to 10,800 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name tanSim (Stratified), tanEnh (Stratified Enhanced), HOut_flow (Enthalpy Flow Rate), HOut_flow1 (Enthalpy Flow Rate). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel tanEnh.vol[2].T covers 293.15 to 301.759 K. At 2,700 s, the primary value is 305.033 and the companion is 298.153. Their signed difference is 6.88 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
![Storage stratified tank. The simulated tanEnh.vol[1].T channel runs from 293.15 to 307.062 K over 10,800 seconds.](https://static.wixstatic.com/media/21e41b_4f92e860623342f88af65b89fdbfc48c~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_4f92e860623342f88af65b89fdbfc48c~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 108 seconds. Subtracting 293.15 from 293.86 gives 0.7102 K. Its location brackets the change within one saved interval of 108 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | tanEnh.vol[1].T (K) | tanEnh.vol[2].T (K) |
|---|---|---|
0 | 293.15 | 293.15 |
108 | 293.8602 | 293.1636 |
2160 | 303.4321 | 296.7215 |
3564 | 307.0618 | 300.4852 |
4320 | 304.5832 | 301.7589 |
6480 | 304.5693 | 301.7486 |
8640 | 303.0738 | 299.8183 |
10800 | 300.6731 | 297.4308 |
What to check on site
Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
Cover photograph by Daniel Dan, via Pexels. The photograph illustrates the subject. Industry Applied produced the figure and calculations from the linked source.