The temperatureSensor.T trace covers 20 to 77.386 °C, a temperature span of 57.386 K. The first recorded maximum occurs at 136,512 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
The RWTH Aachen University E.ON Energy Research Center publishes the AixLib test named StorageSolarCollector. The source file places it under Fluid, Storage. We used the 101 stored values for temperatureSensor.T over the interval 0 to 172,800 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 6 recorded variables. Alongside the primary output there are bufferStorage.layer[10].T, bufferStorage.layer[5].T, bufferStorage.layer[1].T, temperatureSensor.T, solarThermal.Irradiation. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel bufferStorage.layer[1].T covers 299.319 to 345.667 K. At 44,928 s, the primary value is 347.516 and the companion is 301.655. Their signed difference is 45.861 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 1,728 seconds. Subtracting 293.15 from 298.282 gives 5.132 K. Its location brackets the change within one saved interval of 1,728 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | temperatureSensor.T (K) | bufferStorage.layer[1].T (K) |
|---|---|---|
0 | 293.15 | 333.15 |
1728 | 298.2819 | 328.6687 |
34560 | 321.7768 | 304.6756 |
69120 | 341.3586 | 320.3106 |
103680 | 340.9945 | 301.6159 |
136512 | 350.5359 | 341.3349 |
138240 | 350.2064 | 340.0083 |
172800 | 344.3402 | 344.1542 |
What to check on site
Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.