The vol.T trace covers 20 to 39.74 °C, a temperature span of 19.74 K. The first recorded maximum occurs at 5,400 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named ExpansionVessel. The source file places it under Fluid, Storage. We used the 101 stored values for vol.T over the interval 0 to 7,200 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name expVes (Expansion Vessel), vol (Mixing Volume), pulse (Pulse), preTem (Prescribed Temperature). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel expVes.port_a.p starts at 300,000, ends at 300,024 and has a recorded range of 300,000 to 301,754 Pa. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Storage expansion vessel. The simulated vol.T channel runs from 293.15 to 312.89 K over 7,200 seconds.
Storage expansion vessel. The simulated vol.T channel runs from 293.15 to 312.89 K over 7,200 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0 to 72 seconds. Subtracting 293.15 from 296.318 gives 3.168 K. Its location brackets the change within one saved interval of 72 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

vol.T (K)

expVes.port_a.p (Pa)

0

293.15

300000

72

296.3182

300206.3

1440

312.5243

301708

2880

294.6209

300095.8

4320

309.6453

301393

5400

312.8903

301754.3

5760

301.43

300608.5

7200

293.4122

300023.5

What to check on site

Identify the stored quantity and the boundary through which energy or mass enters. A layer temperature, outlet temperature and volume mean describe different states. Preserve initial inventory and the sequence of charge or discharge when repeating the case.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.