The archived response ranges from -579 to 300. The median is -162 and the central half of the measurements extends from -451 to 93. Those figures use all 200 numeric observations in this source series and retain its original measurement scale.

What was measured

The LEW data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as deflection of beam from center point. It preserves the source scale and its sign. The file contains 1 numeric field per accepted row.

Spread across the original readings

The tenth percentile is -554.5 and the ninetieth is 182.5. They provide a narrower description of the typical spread than the minimum and maximum. The largest and smallest observed records are separated by 879. This is the range of this sample, rather than a guaranteed operating envelope.

Steel-concrete beam deflection. The 25th, 50th and 75th percentiles of the measurements are -451, -162 and 93.
Steel-concrete beam deflection. The 25th, 50th and 75th percentiles of the measurements are -451, -162 and 93. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 120 after the header. Its response is -160. The overall arithmetic mean is -177.435, so this observation is 17.435 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 544, calculated by subtracting -451 from 93.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

Percentile

Observed response (source scale)

Number of numeric rows

0

-579

200

10

-554.5

200

25

-451

200

50

-162

200

75

93

200

90

182.5

200

100

300

200

Implications for an industrial comparison

A production acceptance sample should identify the item, instrument, operator and measurement method before the result is pooled. Document fixture setup and any intermediate processing. Repeatability from one instrument and reproducibility across operators or locations require different comparison groups.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data