The recorded vol.m_flow channel spans 4.62e-07 to 0.9856 kg/s in this reference run. It starts at 0.9856 and ends at 0.4996. The first recorded maximum occurs at 0 seconds and the first minimum at 64,800 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SingleBoiler. The source file places it under DHC, Plants, Steam. We used the 101 stored values for vol.m_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name pla (Single Boiler), vol (Control Volume Condensation), res (Pressure Drop), steTra (Steam Trap). The source declares pSat = 300000, m_flow_nominal = 1, dpPip = 6000. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel pumCNR.P starts at 12.854, ends at 8.331 and has a recorded range of 8.94e-05 to 13.095 W. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
Integrating the signed rate over 86,400 seconds gives a net 39,120 kg. This estimate averages neighbouring stored rates and multiplies by their time separation. Reverse flow reduces the net total. If a process requires gross throughput, calculate forward and reverse transfers separately at the appropriate boundary.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | vol.m_flow (kg/s) | pumCNR.P (W) |
|---|---|---|
0 | 0.9856249 | 12.85368 |
864 | 0.5308775 | 8.719238 |
17280 | 0.7647858 | 13.0931 |
34560 | 0.7647858 | 13.0931 |
51840 | 0.206307 | 5.502007 |
64800 | 4.621029e-07 | 8.941194e-05 |
69120 | 0.02441752 | 4.477497 |
86400 | 0.4996253 | 8.331191 |
What to check on site
Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.