The recorded bui[2].Q_flow channel spans 100,000 to 300,000 W in this reference run. It starts at 100,000 and ends at 100,000. The first recorded maximum occurs at 36,288 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named DistributionCondensatePipe. The source file places it under DHC, Networks, Steam. We used the 101 stored values for bui[2].Q_flow over the interval 0 to 86,400 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name souSte (Boundary p T), sinWat (Boundary p T). The source declares pSat = 150000, Q1_flow_nominal = 200E3, Q2_flow_nominal = 300E3, dp_nominal = 6000. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel bui[1].Q_flow covers 50,000 to 200,000 W. At 36,288 s, the primary value is 300,000 and the companion is 50,000. Their signed difference is 250,000 W, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Steam heating distribution network. The simulated bui[2].Q_flow channel runs from 100,000 to 300,000 W over 86,400 seconds.
Steam heating distribution network. The simulated bui[2].Q_flow channel runs from 100,000 to 300,000 W over 86,400 seconds. Figure by Industry Applied.

Reproduce the calculation

Integrating the signed bui[2].Q_flow samples by the trapezoidal rule gives 5,500 kWh over 86,400 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

bui[2].Q_flow (W)

bui[1].Q_flow (W)

0

100000

200000

17280

180000

200000

34560

290000

50000

36288

300000

50000

51840

300000

50000

64800

300000

50000

65664

292000

75000

69120

260000

75000

86400

100000

75000

What to check on site

Compare fuel or electrical input with useful heat at a declared delivery boundary. Include the warm-up interval and any period on standby. Separate a temperature setpoint from the measured outlet and keep auxiliary energy in a stated part of the balance.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.