The h trace ranges from 0.56338 to 6.7058 across 101 saved checkpoints. It begins at 6.7058 and finishes at 0.56338 after 50 s of test time. The reference export does not state a verified engineering unit for this value. Use its native scale when comparing another run of the same model.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named FiniteLineSource_SteadyState. The source file places it under Fluid, Geothermal, Borefields, Heat Transfer, Thermal Response Factors. We used the 101 stored values for h over the interval 0 to 50 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name dis (Distance), hRea (Real), hMir (Real), h (Real). The source declares len1 = 150.0, burDep1 = 4.0, len2 = 125.0, burDep2 = 3.5. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The two named channels have separate paths in the model. h begins at 6.7058 and ends at 0.56338. hRea begins at 7.3662 and ends at 1.1174. The reference export supplies numerical samples but does not attach a physical unit to these fields. Use the linked model declarations to establish the quantity and units of each channel before calculating a difference or assigning it a physical meaning.
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 0 to 0.5 seconds. Subtracting 6.706 from 4.678 gives -2.028 source units. Its location brackets the change within one saved interval of 0.5 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | h (source units) | hRea (source units) |
|---|---|---|
0 | 6.705767 | 7.366243 |
0.5 | 4.677652 | 5.338088 |
10 | 1.871549 | 2.521557 |
20 | 1.251382 | 1.880004 |
30 | 0.9215473 | 1.525618 |
40 | 0.710456 | 1.289345 |
50 | 0.5633766 | 1.117446 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Checking the two recorded channels
At 0.5 s, h reads 4.6777 and hRea reads 5.3381. Across the run, the second channel ranges from 1.1174 to 7.3662. Compare the timing of changes on the two traces. A numerical difference between these channels has no demonstrated physical meaning without matching quantity definitions and units.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.