The TBorFieIn[1].T trace covers 1.719 to 14.863 °C, a temperature span of 13.144 K. The first recorded maximum occurs at 31,536,000 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SteadyStateBoreholeDynamics. The source file places it under Fluid, Geothermal, Zoned Borefields. We used the 101 stored values for TBorFieIn[1].T over the interval 0 to 31,536,000 seconds. This is a simulated test with specified inputs and boundaries.
The reference file contains 6 recorded variables. Alongside the primary output there are TBorFieIn[1].T, TBorFieOut[1].T, TBorFieIn[2].T, TBorFieOut[2].T, borHol.TBorAve[1]. The source and the export are linked independently below so that each reading can be traced back to its calculated channel.
Compare the recorded channels
The companion channel TBorFieOut[1].T covers 274.137 to 287.262 K. At 946,080 s, the primary value is 277.987 and the companion is 277.236. Their signed difference is 0.7509 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.
![Steady-state borehole dynamics. The simulated TBorFieIn[1].T channel runs from 274.869 to 288.013 K over 31,536,000 seconds.](https://static.wixstatic.com/media/21e41b_27368e980df944c5abde3fc28809389f~mv2.png/v1/fill/w_616,h_345,al_c,q_85,enc_auto/21e41b_27368e980df944c5abde3fc28809389f~mv2.png)
Reproduce the calculation
The largest absolute change between consecutive stored points appears from 25,859,520 to 26,174,880 seconds. Subtracting 281.904 from 286.018 gives 4.114 K. Its location brackets the change within one saved interval of 315,360 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | TBorFieIn[1].T (K) | TBorFieOut[1].T (K) |
|---|---|---|
0 | 274.8883 | 274.1375 |
4099680 | 274.8689 | 274.8689 |
6307200 | 279.9166 | 279.1657 |
1.26144e+07 | 282.5548 | 281.8039 |
1.89216e+07 | 280.457 | 280.457 |
2.52288e+07 | 281.9141 | 281.9141 |
2.585952e+07 | 281.904 | 281.904 |
2.617488e+07 | 286.0182 | 285.2674 |
3.1536e+07 | 288.0126 | 287.2617 |
What to check on site
The thermal history of a borefield matters across repeated loads. Distinguish a fluid outlet reading from pipe wall, grout and far-field temperatures. Record the duration and sign of each heat pulse before comparing an installation with a reference case.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.
![Steady-state borehole dynamics. Range and median of consecutive groups of recorded samples. TBorFieIn[1].T (K). 1.26M to 30.6M.](/story-art/2daf72cc75c5a0c9e.webp)