The lowest observed group mean is 59.75 for oven temp group -1. The highest is 82.75 for group 1, a difference of 23 on the source response scale. Across all 8 numeric records the response median is 71.

What was measured

The BOXSPRIN data file has 25 header lines before the tabulated area. The header supplies the test context, column order and reading instructions. This analysis uses the column described as percent acceptable springs. It preserves the source scale and its sign. The file contains 4 numeric fields per accepted row.

Spread across the original readings

The two endpoint groups have 4 and 4 observations. Their medians are 60 and 83, respectively. The figure groups the original entries by the recorded oven temp value. Where there are more than eight distinct settings, it groups them at empirical quartiles and labels each band with its observed endpoints.

Spring acceptance after heat treatment. The lowest and highest group means are 59.75 and 82.75 on the source response scale.
Spring acceptance after heat treatment. The lowest and highest group means are 59.75 and 82.75 on the source response scale. Figure by Industry Applied.

One row you can check

To check a real observation, take numeric row 4 after the header. Its response is 75. The overall arithmetic mean is 71.25, so this observation is 3.75 units from the mean on the original scale. Sorting the whole response gives an interquartile spread of 20.5, calculated by subtracting 60.5 from 81.

The centre and spread are descriptive statistics. Each numeric observation carries the same weight in the overall summary. Treat grouped results as a way to find a measurement difference worth investigating. They do not adjust simultaneously for all factors, run order, sample selection or repeated measurements in the original study.

Worked data

oven temp group

Observations

Mean response

Median response

Minimum response

Maximum response

-1

4

59.75

60

52

67

1

4

82.75

83

75

90

Implications for an industrial comparison

Keep the measurement location, observation interval and averaging rule beside the figure. An extreme in a short record cannot supply a design return period. When comparing installations or environmental records, check whether both instruments observed the same temporal and spatial scale.

Choose a decision threshold in the engineering units before collecting a local series. Preserve raw readings, any exclusions and a record of the operating conditions so that a later analyst can separate a real change from differences in data handling.

Source file and worked data

The original NIST Dataplot header and measurements include the study attribution. Download the complete source file. Download the worked data used in the figure.