The hum.sta_b.T trace covers 10.272 to 19.998 °C, a temperature span of 9.725 K. The first recorded maximum occurs at 0 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SprayAirWasher_X. The source file places it under Fluid, Humidifiers. We used the 101 stored values for hum.sta_b.T over the interval 0 to 1,080 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name sin (Boundary p T), sou1 (Mass Flow Source T), senHum (Mass Fraction Two Port). The source declares m_flow_nominal = 0.1. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel senHum.X starts at 0.01, ends at 0.01 and has a recorded range of 0.01 to 0.014 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Spray air washer model, configured as steady-state. The simulated hum.sta_b.T channel runs from 283.422 to 293.148 K over 1,080 seconds.
Spray air washer model, configured as steady-state. The simulated hum.sta_b.T channel runs from 283.422 to 293.148 K over 1,080 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 540 to 550.8 seconds. Subtracting 283.422 from 293.148 gives 9.725 K. Its location brackets the change within one saved interval of 10.8 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

hum.sta_b.T (K)

senHum.X (source units)

0

293.1476

0.010001

216

288.2767

0.012

367.2

283.4221

0.013999

432

283.4221

0.013999

540

283.4221

0.013999

550.8

293.1476

0.010001

648

293.1476

0.010001

864

293.1476

0.010001

1080

293.1476

0.010001

What to check on site

Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.