The recorded phi.y channel spans 0.001 to 1.001 source units in this reference run. It starts at 0.001 and ends at 1.001. The first recorded maximum occurs at 1 seconds and the first minimum at 0 seconds.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SpecificEnthalpy_TDryBulPhi. The source file places it under Controls, OBC, CDL, Psychrometrics. We used the 101 stored values for phi.y over the interval 0 to 1 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name hBulPhi (Specific Enthalpy T Dry Bul Phi), phi (Ramp), TDryBul (Constant). These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel hBulPhi.h starts at 29,641, ends at 96,720 and has a recorded range of 29,641 to 96,720 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Specific enthalpy t dry bul phi. The simulated phi.y channel runs from 0.001 to 1.001 source units over 1 seconds.
Specific enthalpy t dry bul phi. The simulated phi.y channel runs from 0.001 to 1.001 source units over 1 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 0.99 to 1 seconds. Subtracting 0.991 from 1.001 gives 0.01 source units. Its location brackets the change within one saved interval of 0.01 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

phi.y (source units)

hBulPhi.h (source units)

0

0.001

29640.76

0.2

0.201

42618.42

0.4

0.401

55809.73

0.6

0.601

69219.99

0.8

0.801

82854.72

0.99

0.991

96020.8

1

1.001

96719.59

What to check on site

Record the physical quantity and its reference state before checking agreement. A sensor model can include a delay or mixing volume that an algebraic reference omits. Align both acquisition time and location before interpreting a difference as calibration error.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model

Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.