The rooMulSpe.vol.T trace covers 16.001 to 26.598 °C, a temperature span of 10.598 K. The first recorded maximum occurs at 16,119,648 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.

The system being tested

Lawrence Berkeley National Laboratory publishes the Buildings test named SpaceCooling. The source file places it under Fluid, direct expansion Systems, Cooling, Air Source. We used the 101 stored values for rooMulSpe.vol.T over the interval 15,811,200 to 16,416,000 seconds. This is a simulated test with specified inputs and boundaries.

The component declarations name datCoi (direct expansion Coil), fan (Flow Controlled m flow), hex (Constant Effectiveness), out (Outside). The source declares V = 6*10*3, eps = 0.8, TASup_nominal = 273.15 + 18, TRooSet = 273.15 + 24. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.

Compare the recorded channels

The companion channel mulSpePow.y starts at 0, ends at 681,954,240 and has a recorded range of 0 to 681,954,240 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Space cooling with direct expansion coils. The simulated rooMulSpe.vol.T channel runs from 289.151 to 299.748 K over 604,800 seconds.
Space cooling with direct expansion coils. The simulated rooMulSpe.vol.T channel runs from 289.151 to 299.748 K over 604,800 seconds. Figure by Industry Applied.

Reproduce the calculation

The largest absolute change between consecutive stored points appears from 15,811,200 to 15,817,248 seconds. Subtracting 293.15 from 290.123 gives -3.027 K. Its location brackets the change within one saved interval of 6,048 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.

The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.

Worked data

Simulation time (s)

rooMulSpe.vol.T (K)

mulSpePow.y (source units)

1.58112e+07

293.15

0

1.581725e+07

290.1234

0

1.582934e+07

289.1508

0

1.593216e+07

296.6636

2.81402e+07

1.605312e+07

297.068

3.10747e+08

1.611965e+07

299.7483

4.333911e+08

1.617408e+07

296.6094

4.951438e+08

1.629504e+07

296.7899

5.916106e+08

1.6416e+07

291.4366

6.819542e+08

What to check on site

Read the evaporator, condenser and electrical channels at the same duty. The water or air temperatures entering the equipment constrain capacity and efficiency. A compressor command does not specify how much heat actually crosses the useful-load boundary.

State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.

Data and source model