The senTemHXOut.T trace covers 11.521 to 25.28 °C, a temperature span of 13.759 K. The first recorded maximum occurs at 15,590,880 seconds. The numerical source and data table retain the original kelvin values. Subtract 273.15 only when converting an absolute temperature to Celsius.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SpaceCooling. The source file places it under Fluid, Heat Exchangers, Thermal Wheels, Latent. We used the 101 stored values for senTemHXOut.T over the interval 15,552,000 to 15,638,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name vol (Mixing Volume), theCon (Thermal Conductor), TOut (Prescribed Temperature), preHea (Fixed Heat Flow). The source declares V = 6*10*3, TASup_nominal = 291.15, wASup_nominal = 0.012, TRooSet = 297.15. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel TOut.T covers 284.671 to 300.313 K. At 15,569,280 s, the primary value is 293.15 and the companion is 285.137. Their signed difference is 8.013 K, the largest absolute separation on the common grid. Check the two channels’ physical roles before interpreting that difference as any kind of error.

Reproduce the calculation
The largest absolute change between consecutive stored points appears from 15,569,280 to 15,570,144 seconds. Subtracting 293.15 from 284.806 gives -8.344 K. Its location brackets the change within one saved interval of 864 seconds. It does not identify an unobserved instantaneous peak or the exact crossing time.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | senTemHXOut.T (K) | TOut.T (K) |
|---|---|---|
1.5552e+07 | 293.15 | 291.45 |
1.556928e+07 | 293.15 | 285.1369 |
1.557014e+07 | 284.8058 | 284.8055 |
1.557101e+07 | 284.6712 | 284.6711 |
1.558656e+07 | 295.9835 | 295.9844 |
1.559088e+07 | 298.4297 | 298.5576 |
1.560384e+07 | 298.1591 | 300.0142 |
1.562112e+07 | 298.255 | 292.6542 |
1.56384e+07 | 298.255 | 290.55 |
What to check on site
Record the hot and cold boundary conditions as well as the response inside the component. For a steady comparison, check that stored heat has stopped changing. For a transient comparison, keep the timing and the observation location with every reported value.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.