The recorded fan.P channel spans 0 to 717.44 W in this reference run. It starts at 0 and ends at 717.44. The first recorded maximum occurs at 15,638,400 seconds and the first minimum at 15,552,000 seconds.
The system being tested
Lawrence Berkeley National Laboratory publishes the Buildings test named SpaceCooling. The source file places it under Fluid, Air Filters. We used the 101 stored values for fan.P over the interval 15,552,000 to 15,638,400 seconds. This is a simulated test with specified inputs and boundaries.
The component declarations name theCon (Thermal Conductor), TOut (Prescribed Temperature), preHea (Fixed Heat Flow), fan (Flow Controlled m flow). The source declares V = 6*10*3, eps = 0.8, TASup_nominal = 291.15, wASup_nominal = 0.012. These identifiers can be found in the linked model definition. Check how they connect to the plotted quantity before comparing it with a field meter or a differently named controller tag.
Compare the recorded channels
The companion channel C_inflow.y starts at 7.73e-09, ends at 1.15e-08 and has a recorded range of 7.73e-09 to 1.15e-08 source units. Its time span matches the primary channel. Both are included to put the primary response in context. Their numerical scales may represent different physical quantities.

Reproduce the calculation
Integrating the signed fan.P samples by the trapezoidal rule gives 17.132 kWh over 86,400 seconds. For each pair, average the two powers in watts and multiply by the interval in seconds. Sum the watt-seconds and divide by 3,600,000. This value refers to the selected simulation connector and should be assigned to a physical load only after confirming the boundary and sign.
The worked table retains the first and last points, the primary maximum and minimum, the largest adjacent change and a spread of checkpoints across the run. Rounding is for presentation. Use the full linked reference series to repeat integrals or compare events between checkpoints. The archived sampling interval need not match the simulation solver’s internal step.
Worked data
Simulation time (s) | fan.P (W) | C_inflow.y (source units) |
|---|---|---|
1.5552e+07 | 0 | 7.733952e-09 |
1.555286e+07 | 717.4382 | 7.733952e-09 |
1.556928e+07 | 717.4385 | 7.733952e-09 |
1.558656e+07 | 717.4387 | 7.733952e-09 |
1.560384e+07 | 717.439 | 8.443781e-09 |
1.562112e+07 | 717.4394 | 9.969382e-09 |
1.56384e+07 | 717.4398 | 1.149498e-08 |
What to check on site
Identify which part of the system the selected output represents, and retain the surrounding boundary conditions. Compare the same event and operating duty in both records. Record the equipment configuration if a later change could alter the test result.
State the operating duty, measurement location and expected tolerance before evaluating a local trend. Re-run the comparison with the installed controls and instruments during a representative operating period. Retain the native units and the raw export so that a later change in software or presentation can be investigated.
Data and source model
Published model and component definitions. Numerical reference series. Simulation and plot commands. Download the worked checkpoints in CSV format.